·Î±×ÀÎ
Ä¡ÀÇÇÐ µµ¼­
Àú³Î
¿µ¹®¿ø¼­
Ä¡±â°ø»ç µµ¼­
Ä¡À§»ý»ç µµ¼­
Ä¡°ú´ëÇÐ ±³°ú¼­
Ä¡ÀÇÇÐ ÃֽŠ½Å°£

Ä¡°ú °ü·Ã »çÀÌÆ®
ÀÚÀ¯°Ô½ÃÆÇ
»ç¿ëÈı⠸ðÀ½
 010-8764-7622
ÆòÀÏ 09:00 ~ 18:00
ÁÖ¸» 09:00 ~ 14:00
¹®ÀÇ»çÇ× ¾ðÁ¦µçÁö
E-mail ¹®ÀÇ
±¹¹Î 066- 21- 0720- 889
¿ì¸® 184- 07- 082338
Çϳª 153- 110489- 00108
³óÇù 352- 0594- 8175 53
¿¹±ÝÁÖ: ³ë»óÁ¾
 

 
ºñ¹Ð¹øÈ£ È®ÀÎ ´Ý±â
Ä¡ÀÇÇÐ µµ¼­ > ÀÓÇÁ¶õÆ® > ¢ºÁõ·Ê·Î º¸´Â ´Ù¾çÇÑ ÀÓÇÁ¶õÆ® º¸Ã¶¼öº¹ÇÐ
Ä¡ÀÇÇÐ µµ¼­


¢ºÁõ·Ê·Î º¸´Â ´Ù¾çÇÑ ÀÓÇÁ¶õÆ® º¸Ã¶¼öº¹ÇÐ
ÀúÀÚ : ±è¼¼¿õ
¿ªÀÚ :
Á¤°¡ : 165,000¿ø
ÆǸŰ¡°Ý : 165,000¿ø
Àû¸³±Ý¾× : 16,500¿ø
¼ö·® EA
 
    

 
»óÇ° »ó¼¼ ¼³¸í
 
 

¹ßÇàÀÏ: 2005.05.01, 729p, Ä®¶óÀμâ

ÃâÆÇ: ¸í¹®ÃâÆÇ»ç

¸ñÂ÷

1Àå Implant »óºÎ ±¸Á¶¹° Á¦ÀÛÀ» À§ÇÑ impression methods
¡¡
1 Impression time
2 Classification
(1) ¸ñÀû¿¡ µû¸¥ ºÐ·ù
(2) Impression level¿¡ µû¸¥ ºÐ·ù
1) Fixture level impression
2) Abutment level impression
(3) Impression coping¿¡ µû¸¥ ºÐ·ù
1) Transfer type impression / 2) Pick-up type impression
(4) Solid abutment¸¦ ÀÌ¿ëÇÏ´Â internal connection system
3 Implant ½Ä¸³ ´çÀÏ impression(index)¸¦ äµæÇÏ´Â °æ¿ì
4 Guided gingival formÀ» ¸ðÇü»ó¿¡ Ç¥ÇöÇϱâ À§ÇÑ Àλóäµæ ¹æ¹ý
5 Conventional impression method

2Àå Master modelÀÇ Á¦ÀÛ

3Àå Implant abutment system

1 ´Ù¾çÇÑ abutmentÀÇ ÃâÇö
2 Implant abutment ¼±Åýà °í·Á»çÇ×
3 Implant system¿¡ µû¸¥ abutmentÀÇ Á¾·ù
4 Implant »óºÎ ±¸Á¶¹°ÀÇ Á¦ÀÛ °úÁ¤
- Replace select systemÀ» ÅëÇÑ implant »óºÎ ±¸Á¶¹° Á¦ÀÛ °úÁ¤ÀÇ ÀÌÇØ
5 External connection system V/S internal connection system

6 º¸Ã¶Àû °üÁ¡¿¡¼­ ¹Ù¶óº» fixture / abutment connection typeÀÇ ¼±ÅÃ
7 UCLA abutment¿¡ ´ëÇÑ ÀÌÇØ

4Àå Table Clinic - OSSTEM implant systemÀ» ÀÌ¿ëÇÑ implant »óºÎ ±¸Á¶¹°ÀÇ Á¦ÀÛ °úÁ¤

1 External connection system
(1)Cemented abutment
(2)Esthetic abutment
(3)UCLA abutment (ÀüÄ¡ºÎ)
(4)UCLA abutment (±¸Ä¡ºÎ)
(5)SCRP abutment
2 Internal connection system
(1)Solid abutment (Option A)
(2)ComOcta cemented abutment
(3)Octa abutment (±¸Ä¡ºÎ)
(4)Octa abutment (ÀüÄ¡ºÎ)

5Àå Case Presentation - Part I OSSTEM implant system
¡¡
1 OSSTEM implant systemÀÇ solid abutment¸¦ ÀÌ¿ëÇÑ Áõ·Ê
-Implant »óºÎ ±¸Á¶¹°ÀÇ ¿¬°á ¹æ½Ä
2 OSSTEM implant systemÀÇ Excellent solid abutment¸¦ ÀÌ¿ëÇÑ Áõ·Ê
(1)Regular platformÀÇ fixture¿¡¼­ Excellent solid abutment¸¦ ÀÌ¿ëÇÑ Áõ·Ê
(2) Wide neck implant fixture¿¡¼­ Excellent solid abutment¸¦ ÀÌ¿ëÇÑ Áõ·Ê
3 OSSTEM systemÀÇ ComOcta cemented abutment¸¦ ÀÌ¿ëÇÑ Áõ·Ê
-Solid abutment¿Í ComOcta cemented abutmentÀÇ ºñ±³
4 OSSTEM systemÀÇ ComOcta cemented abutment¸¦ ÀÌ¿ëÇÑ Áõ·Ê
-»óºÎ ±¸Á¶¹°ÀÇ ±³ÇÕ¸é Àç·á¿¡ ´ëÇÑ °í·Á »çÇ×
5 OSSTEM systemÀÇ ComOcta cemented abutment¸¦ ÀÌ¿ëÇÑ Áõ·Ê
-ImplantÀÇ ½Ä¸³ À§Ä¡°¡ ÆòÇàÇÏÁö ¾ÊÀ» °æ¿ì °¢µµ¸¦ ¼öÁ¤ÇÏ´Â ¹æ¹ý
-ImplantÀÇ ½Ä¸³ À§Ä¡°¡ ÆòÇàÇÏÁö ¾Ê¾Æ Angled abutment¸¦ »ç¿ëÇÑ Áõ·Ê

6 OSSTEM systemÀÇ ComOcta cemented abutment¸¦ ÀÌ¿ëÇÑ Áõ·Ê
-Wide diameter implant V/S Double implant
7 OSSTEM systemÀÇ ComOcta-Plus cemented abutment¸¦ ÀÌ¿ëÇÑ Áõ·Ê
8 OSSTEM systemÀÇ ComOcta & ComOcta-Plus cemented abutment(Internal)¿Í external connection typeÀÇ cemented abutment¸¦ ÀÌ¿ëÇÑ Áõ·Ê
-Cement À¯ÁöÇü »óºÎ ±¸Á¶¹°ÀÇ º¯¿¬ À§Ä¡
9 OSSTEM systemÀÇ angled abutment¸¦ ÀÌ¿ëÇÑ Áõ·Ê

6Àå Case presentation - Part II XiVE implant system

1 XiVE systemÀÇ EsthetiBase abutment¸¦ ÀÌ¿ëÇÑ #46ÀÇ ¼öº¹ Áõ·Ê
-XiVE implant systemÀÇ impression methods
2 ±³Á¤ Ä¡·á ÈÄ XiVE systemÀÇ EsthetiBase abutment¸¦ ÀÌ¿ëÇÑ #46ÀÇ ¼öº¹ Áõ·Ê
-Zirconia copingÀ» ÀÌ¿ëÇÑ AllCeramic restoration (Áõ·Ê 1, 2, 3)
3 #35, #45 ºÎÀ§ÀÇ space regaining ÈÄ cemented typeÀ¸·Î Á¦ÀÛÇÑ Áõ·Ê
4 XiVE systemÀÇ EsthetiBase abutment¸¦ ÀÌ¿ëÇÑ #36, #37ÀÇ ¼öº¹ Áõ·Ê
-EsthetiBase abutment¸¦ ÀÌ¿ëÇÑ cemented type »óºÎ ±¸Á¶¹°ÀÇ Á¦ÀÛ °úÁ¤
5 XiVE systemÀÇ TempBase¸¦ ÀÌ¿ëÇÑ provisional restoration Á¦ÀÛ ÈÄ ÃÖÁ¾ »óºÎ ±¸Á¶¹°À» Á¦ÀÛÇÑ Áõ·Ê

6 XiVE systemÀÇ EsthetiBase abutment¸¦ ÀÌ¿ëÇÑ #34, 35, 36, 37ÀÇ ¼öº¹ Áõ·Ê
-»óºÎ ±¸Á¶¹°À» À§ÇÑ metal framework(Coping)ÀÌ Àß ¸ÂÁö ¾Ê´Â °æ¿ì °Ë»ç »çÇ×
-Multiple implant restorationÀÇ °æ¿ì splinting ¿©ºÎ¿¡ ´ëÇÑ °í·Á »çÇ×
-Implant »óºÎ ±¸Á¶¹°ÀÇ º¸Ã¶Àû ¼³°è¿¡ ´ëÇÑ °í·Á »çÇ×
7 XiVE systemÀÇ EsthetiBase abutment¸¦ ÀÌ¿ëÇÏ¿© #35, 36, 37, #45, 46, 47 ºÎÀ§¸¦ cement À¯ÁöÇüÀ¸·Î ¼öº¹ÇÑ Áõ·Ê
8 XiVE systemÀÇ EsthetiBase abutment¸¦ ÀÌ¿ëÇÑ #46, #47ÀÇ ¼öº¹ Áõ·Ê
-XiVE systemÀÇ transversal screw¸¦ ÀÌ¿ëÇÑ screw À¯ÁöÇü »óºÎ ±¸Á¶¹°ÀÇ Á¦ÀÛ
-ITI sysemÀÇ SynOcta TS abutment¸¦ ÀÌ¿ëÇÑ screw typeÀÇ »óºÎ ±¸Á¶¹° Á¦ÀÛ
9 XiVE systemÀÇ EsthetiBase abutment¸¦ ÀÌ¿ëÇÑ #13, 11, 22ÀÇ ¼öº¹ Áõ·Ê
10 XiVE systemÀÇ AuroBase¸¦ ÀÌ¿ëÇÑ screw-retained typeÀÇ »óºÎ ±¸Á¶¹° Á¦ÀÛ
-TempBase¸¦ ÀÌ¿ëÇÑ provisional restorationÀÇ Á¦ÀÛ

11 XiVE systemÀÇ EsthetiBase abutment¸¦ ÀÌ¿ëÇÑ #41ÀÇ ¼öº¹ Áõ·Ê
-ProTect¸¦ ÀÌ¿ëÇÑ provisional restorationÀÇ Á¦ÀÛ
12 XiVE systemÀÇ MP abutment¸¦ ÀÌ¿ëÇÑ screw À¯ÁöÇü »óºÎ ±¸Á¶¹°ÀÇ Á¦ÀÛ
-XiVE systemÀÇ MP abutment¿¡ ´ëÇÑ ÀÌÇØ / *MP abutment¸¦ ÀÌ¿ëÇÑ »óºÎ ±¸Á¶¹°ÀÇ Á¦ÀÛ Áõ·Ê 1, 2, 3
-Screw looseningÀÌ ÀϾ ¼ö ÀÖ´Â ¿äÀΰú ÀÌ°Í¿¡ ´ëÇÑ ¹æÁöÃ¥
13 XiVE systemÀÇ EsthetiBase abutment¿Í AuroBase¸¦ ÀÌ¿ëÇÑ combination typeÀÇ »óºÎ ±¸Á¶¹° Á¦ÀÛ Áõ·Ê
14 ´Ù¼ö Ä¡¾Æ¸¦ À§ÇÑ cement À¯ÁöÇü »óºÎ ±¸Á¶¹°ÀÇ metal framework ÀûÇÕµµ È®ÀÎ ¹æ¹ý
-°íÁ¤ ³ª»ç·Î ÀåÂøÇÏ´Â °æ¿ì(Screw retained type)ÀÇ framework ÀûÇÕ¼º È®ÀÎ

7Àå Case presentation - Part III ±× ¿ÜÀÇ ´Ù¾çÇÑ implant system

1 3i external systemÀÇ GingiHue post¸¦ ÀÌ¿ëÇÑ cement À¯ÁöÇü »óºÎ ±¸Á¶¹°ÀÇ Á¦ÀÛ
-Guidelines for splinting implant
2 Biohorizon systemÀÇ fixture mount¸¦ ÀÌ¿ëÇÑ cement À¯ÁöÇü »óºÎ ±¸Á¶¹°ÀÇ Á¦ÀÛ
3 PITT-EASY BIO-OSS systemÀ» ÀÌ¿ëÇÑ ±¸Ä¡ºÎ ¼öº¹ Áõ·Ê
-Screw- and cement-retained prosthesis ( SCRP)
4 Lifecore stage-1 systemÀÇ indexed abutment¸¦ ÀÌ¿ëÇÑ screw À¯ÁöÇü »óºÎ ±¸Á¶¹°ÀÇ Á¦ÀÛ Áõ·Ê
-Clinical Parameters of Evaluation During Implant Maintenance
5 Lifecore stage-1 systemÀÇ COC abutment¸¦ ÀÌ¿ëÇÑ cement À¯ÁöÇü »óºÎ ±¸Á¶¹°ÀÇ Á¦ÀÛ Áõ·Ê
-COC abutment¸¦ ÀÌ¿ëÇÒ ¶§ abutmentÀÇ Á¶Á¤ÀÌ ÇÊ¿äÇÑ °æ¿ì »óºÎ ±¸Á¶¹°ÀÇ Á¦ÀÛ ¹æ¹ý

6 Endopore systemÀÇ cementable abutment¸¦ ÀÌ¿ëÇÑ cement À¯ÁöÇü »óºÎ ±¸Á¶¹°ÀÇ Á¦ÀÛ Áõ·Ê
-Cement À¯ÁöÇü »óºÎ ±¸Á¶¹°ÀÇ ÇÕÂø½Ã ÀÜÁ¸ cementÀÇ À§Ç輺À» ÁÙÀÌ´Â ¹æ¹ý
7 SwissPlus systemÀÇ narrow straight abutment¸¦ ÀÌ¿ëÇÑ cement À¯ÁöÇü »óºÎ ±¸Á¶¹°ÀÇ Á¦ÀÛ Áõ·Ê I
8 SwissPlus systemÀÇ narrow straight abutment¸¦ ÀÌ¿ëÇÑ cement À¯ÁöÇü »óºÎ ±¸Á¶¹°ÀÇ Á¦ÀÛ Áõ·Ê II
9 SwissPlus systemÀÇ fixture mount¸¦ ÀÌ¿ëÇÑ cement À¯ÁöÇü »óºÎ ±¸Á¶¹°ÀÇ Á¦ÀÛ
10 SwissPlus systemÀÇ Cast-to abutment¸¦ ÀÌ¿ëÇÑ screw À¯ÁöÇü »óºÎ ±¸Á¶¹°ÀÇ Á¦ÀÛ Áõ·Ê

11 Replace Select systemÀÇ Esthetic abutment¸¦ ÀÌ¿ëÇÑ cement À¯ÁöÇü »óºÎ ±¸Á¶¹°ÀÇ Á¦ÀÛ Áõ·Ê
12 Replace Select systemÀÇ Easy abutment¸¦ ÀÌ¿ëÇÑ cement À¯ÁöÇü »óºÎ
13 Replace Select systemÀÇ Esthetic abutment¸¦ ÀÌ¿ëÇÑ cement À¯ÁöÇü »óºÎ ±¸Á¶¹°ÀÇ Á¦ÀÛ Áõ·Ê
14 Replace Select systemÀÇ Angled Esthetic abutment¸¦ ÀÌ¿ëÇÑ ±¸Ä¡ºÎ cement À¯ÁöÇü »óºÎ ±¸Á¶¹°ÀÇ Á¦ÀÛ Áõ·Ê
-Removal of a fractured implant abutment screw / 539
15 Paragon systemÀÇ UCLA abutment¸¦ ÀÌ¿ëÇÑ ÀüÄ¡ºÎ cement À¯ÁöÇü »óºÎ ±¸Á¶¹°ÀÇ Á¦ÀÛ Áõ·Ê
-½É¹ÌÀûÀÎ ºÎÀ§¿¡¼­ÀÇ implant ¼öº¹½Ã °í·ÁÇÒ Á¡

16 Replace Select systemÀÇ Angled Esthetic abutment¸¦ ÀÌ¿ëÇÑ ÀüÄ¡ºÎ cement À¯ÁöÇü »óºÎ ±¸Á¶¹°ÀÇ Á¦ÀÛ Áõ·Ê
-Interproximal papillae
17 3i systemÀÇ GingiHue post¸¦ ÀÌ¿ëÇÑ ÀüÄ¡ºÎ cement À¯ÁöÇüÀÇ »óºÎ ±¸Á¶¹°ÀÇ Á¦ÀÛ Áõ·Ê
-Submergence profile
18 3i systemÀÇ UCLA abutment¸¦ ÀÌ¿ëÇÑ ÀüÄ¡ºÎ cement À¯ÁöÇü »óºÎ ÁÖÁ¶¹°ÀÇ Á¦ÀÛ Áõ·Ê
-½É¹ÌÀûÀÎ implant ¼öº¹À» À§ÇÑ implant fixtureÀÇ ½Ä¸³ À§Ä¡
19 3i systemÀÇ ZiReal post¸¦ ÀÌ¿ëÇÑ ÀüÄ¡ºÎ cement À¯ÁöÇü »óºÎ ÁÖÁ¶¹°ÀÇ Á¦ÀÛ Áõ·Ê
-Surgical stent (Template)
20 ITI implant systemÀÇ solid abutment¸¦ ÀÌ¿ëÇÑ ÀüÄ¡ºÎ cement À¯ÁöÇü »óºÎ ±¸Á¶¹°ÀÇ Á¦ÀÛ Áõ·Ê

8Àå Case presentation - Part IV Implant-supported bar overdenture Implant full mouth rehabilitation
¡¡
1 XiVE TG systemÀ» ÀÌ¿ëÇÑ implant-supported bar overdenture Á¦ÀÛ Áõ·Ê
-Combination syndrome associated with a mandibular implant-supported overdenture
-3i standard abutment¸¦ ÀÌ¿ëÇÑ bar ±¸Á¶¹°ÀÇ Á¦ÀÛ
-Paragon systemÀÇ ACT abutment¸¦ ÀÌ¿ëÇÑ bar ±¸Á¶¹°ÀÇ Á¦ÀÛ
2 OSSTEM SS-II implant systemÀÇ Octa abutment¸¦ ÀÌ¿ëÇÑ implant-supported bar¡¡overdentureÀÇ Á¦ÀÛ Áõ·Ê
-Implant-supported overdentureÀÇ À¯Áö ¹× ÁöÁö ÇüÅÂ
-Clinical methods for evaluating implant framework fit
3 Implant full mouth rehabilitation(Mx.), Implant-supported bar overdenture(Mn.)
4 Maxillary full mouth implant rehabilitation and mandibular full mouth rehabilitation

9Àå Implant fixture mountÀÇ È°¿ë

1 Surgical template(stent)¸¦ Á¦ÀÛÇÒ ¶§ÀÇ È°¿ë
2 Positional index¸¦ Á¦ÀÛÇϴµ¥ È°¿ë
3 Impression copingÀ¸·ÎÀÇ È°¿ë
4 Verification device·ÎÀÇ È°¿ë
5 Provisional abutment ¶Ç´Â final abutment·ÎÀÇ È°¿ë

6 Occlusal registration stopÀ¸·ÎÀÇ È°¿ë
7 Implant - supported recording base Á¦À۽à Ȱ¿ë
8 Healing abutment·ÎÀÇ È°¿ë

Ư¡

ÀÌ Ã¥Àº ÀÓ»óÁõ·Ê À§ÁÖ·Î ¼­¼úÇØ ³ª°¡´Â Çü½ÄÀ» ÃëÇÏ°í ÀÖÀ¸¸ç Áõ·ÊÀÇ ±×¸² ÇÏ´Ü¿¡´Â ±× ±×¸²ÀÌ ÀǹÌÇÏ´Â °Í°ú ÀÓ»ó °úÁ¤µ¿¾È ½Ç¼ö Çß´ø°Í ±×¸®°í ÀÌ·¸°Ô ÇÏ¸é ¾î¶³±î ÇÏ´Â ³»¿ëÀ» ½Ç¾ú½À´Ï´Ù.

ÀÌ Ã¥Àº ºÎºÐ ¹«Ä¡¾Ç ȯÀÚ¿¡¼­ÀÇ °íÁ¤¼º Implant º¸Ã¶°úÁ¤¿¡ ´ëÇÑ °ÍÀÌ ÁÖÀÌ¸ç ¸¶Áö¸· ºÎºÐÀº overdenture¿¡ ´ëÇÑ Áõ·Ê¸¦ º¸À̸鼭 ¼³¸íÀ» Ãß°¡ ÇÏ¿´½À´Ï´Ù.

´Ù¾çÇÑ Implant system¿¡ ´ëÇÑ º¸Ã¶°úÁ¤À» ¼Ò°³ÇÏ·Á ÇÏ¿´À¸¸ç ¼±»ý´Ô²²¼­ ¾²½Ã´Â system¿¡ Àû¿ëÇÏ°í ÀÀ¿ëÇÏ½Ã¾î ¸¹Àº µµ¿òÀÌ µÇ±â¸¦ ¹Ù¶ø´Ï´Ù.

óÀ½ Implant¸¦ Á¢ÇϽô ¼±»ý´ÔµéÀ̳ª Implant ȯÀÚ¸¦ Ä¡·áÇÏ´Â Áß¿¡ º¸Ã¶°úÁ¤¿¡¼­ È¥¶õÀ» °ÞÀ¸¼Ì´ø ¼±»ý´Ôµé¿¡°Ô µµ¿òÀÌ µÇ¾úÀ¸¸é ÇÏ´Â ¹Ù¶øÀÔ´Ï´Ù.

 
 
 
»óÇ° »ç¿ë Èıâ
 
 
À̸§ :
³»¿ë :
ÆòÁ¡
 
 
 
ȸ»ç¼Ò°³ | ÀÌ¿ë¾à°ü | °³ÀÎÁ¤º¸Ãë±Þ¹æħ | ÀÌ¿ë¾È³»  
»óÈ£ : µ§Å»ºÏ | ´ëÇ¥ÀÚ:³ë»óÁ¾ l °³ÀÎÁ¤º¸°ü¸®Ã¥ÀÓÀÚ : ³ë»óÁ¾ l È£½ºÆà Á¦°øÀÚ : (ÁÖ)ÄÚ¸®¾Æ¼¾Å¸
»ç¾÷ÀÚ µî·Ï¹øÈ£ ¾È³» 202-90-06315 202-90-06315 | Åë½ÅÆǸž÷ ½Å°í¹øÈ£ : Áß±¸ 00239È£
ÁÖ¼Ò: ¼­¿ïƯº°½Ã ±¸·Î±¸ ³²ºÎ¼øȯ·Î 95±æ 88 µÎ»ê 102-1512È£ | ÀüÈ­ : 010-8764-7622
Contact ¸ÞÀÏ for more information. Copyright ¨Ï 2007 µ§Å»ºÏ All rights reserved.